  Datasheet File OCR Text:
  optically coupled 20 ma current loop receiver technical data hcpl-4200 features ? data output compatible with lsttl, ttl and cmos ? 20 k baud data rate at 1400 metres line length ? guaranteed performance over temperature (0 c to 70 c) ? guaranteed on and off thresholds ? led is protected from excess current ? input threshold hysteresis ? three-state output compat- ible with data buses ? internal shield for high common mode rejection ? safety approval ul recognized -2500 v rms, for 1 minute csa approved ? optically coupled 20 ma current loop transmitter, hcpl-4100, also available applications ? isolated 20 ma current ? loop receiver in: computer peripherals industrial control equipment data communications equipment description the hcpl-4200 optocoupler is designed to operate as a receiver in equipment using the 20 ma current loop. 20 ma current loop systems conventionally sig- nal a logic high state by transmit- ting 20 ma of loop current (mark), and signal a logic low state by allowing no more than a few milliamperes of loop current (space). optical coupling of the signal from the 20 ma current loop to the logic output breaks ground loops and provides for a very high common mode rejection. the hcpl-4200 aids in the design process by providing guaranteed thresholds for logic high state and logic low state for the current loop, providing an lsttl, ttl, or cmos compatible logic interface, and providing guaranteed common mode rejection. the buffer circuit on the current loop side of the hcpl-4200 provides typically 0.8 ma of hysteresis which increases the immunity to common mode and differential mode noise. the buffer also provides a controlled amount of led drive current which takes into account any led light output degradation. the internal shield allows a guaranteed 1000 v/ m s common mode transient immunity. caution: it is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation which may be induced by esd. functional diagram a 0.1 m f bypass capacitor connected between pins 8 and 5 is recommended.
2 ordering information specify part number followed by option number (if desired). hcpl-4200# xxx 300 = gull wing surface mount lead option 500 = tape/reel package option (1 k min) option data sheets available. contact your agilent sales representative or authorized distributor for information. package outline drawings e 8 pin dip package (hcpl-4200) 8 pin dip package with gull wing surface mount option 300 (hcpl-4200) 0.635 ?0.25 (0.025 ?0.010) 12?nom. 9.65 ?0.25 (0.380 ?0.010) 0.635 ?0.130 (0.025 ?0.005) 7.62 ?0.25 (0.300 ?0.010) 5 6 7 8 4 3 2 1 9.65 ?0.25 (0.380 ?0.010) 6.350 ?0.25 (0.250 ?0.010) 1.016 (0.040) 1.194 (0.047) 1.194 (0.047) 1.778 (0.070) 9.398 (0.370) 9.906 (0.390) 4.826 (0.190) typ. 0.381 (0.015) 0.635 (0.025) pad location (for reference only) 1.080 ?0.320 (0.043 ?0.013) 4.19 (0.165) max. 1.780 (0.070) max. 1.19 (0.047) max. 2.54 (0.100) bsc dimensions in millimeters (inches). lead coplanarity = 0.10 mm (0.004 inches). 0.254 + 0.076 - 0.051 (0.010 + 0.003) - 0.002) 9.65 ?0.25 (0.380 ?0.010) 1.78 (0.070) max. 1.19 (0.047) max. a xxxx yyww date code 1.080 ?0.320 (0.043 ?0.013) 2.54 ?0.25 (0.100 ?0.010) 0.51 (0.020) min. 0.65 (0.025) max. 4.70 (0.185) max. 2.92 (0.115) min. dimensions in millimeters and (inches). 5 6 7 8 4 3 2 1 5?typ. type number ul recognition ur 0.254 + 0.076 - 0.051 (0.010 + 0.003) - 0.002) 7.62 ?0.25 (0.300 ?0.010) 6.35 ?0.25 (0.250 ?0.010)
3 thermal profile (option #300) 240 d t = 115?, 0.3?/sec 0 d t = 100?, 1.5?/sec d t = 145?, 1?/sec time ?minutes temperature ?? 220 200 180 160 140 120 100 80 60 40 20 0 260 123 456789101112 figure 1. maximum solder reflow thermal profile. (note: use of non-chlorine activated fluxes is recommended.) regulatory information the hcpl-4200 has been approved by the following organizations: ul recognized under ul 1577, component recognition program, file e55361. csa approved under csa component acceptance notice #5, file ca 88324. insulation and safety related specifications parameter symbol value units conditions min. external air gap l(io1) 7.1 mm measured from input terminals to output (external clearance) terminals, shortest distance through air min. external tracking path l(io2) 7.4 mm measured from input terminals to output (external creepage) terminals, shortest distance path along body min. internal plastic gap 0.08 mm through insulation distance, conductor to (internal clearance) conductor, usually the direct distance between the photoemitter and photodetector inside the optocoupler cavity tracking resistance cti 200 volts din iec 112/vde 0303 part 1 (comparative tracking index) isolation group iiia material group (din vde 0110, 1/89, table 1) option 300 C surface mount classification is class a in accordance with cecc 00802.
4 absolute maximum ratings (no derating required up to 70 c) storage temperature .................................................. -55 c to +125 c operating temperature ................................................. -40 c to +85 c lead solder temperature .... 260 c for 10 s (1.6 mm below seating plane) supply voltage e v cc .............................................................. 0 v to 20 v average input current - i i ........................................... -30 ma to 30 ma peak transient input current - i i ............................................... 0.5 a [1] enable input voltage e v e ................................................ -0.5 v to 20 v output voltage e v o ........................................................ -0.5 v to 20 v average output current e i o ....................................................... 25 ma input power dissipation e p i ................................................... 90 mw [2] output power dissipation e p o ............................................. 210 mw [3] total power dissipation e p .................................................. 255 mw [4] infrared and vapor phase reflow temperature (option #300) .......................................... see fig. 1, thermal profile recommended operating conditions parameter symbol min. max. units power supply voltage v cc 4.5 20 volts forward input current i si 0 2.0 ma (space) forward input current i mi 14 24 ma (mark) operating temperature t a 070 c fan out n 0 4 ttl loads logic low enable v el 0 0.8 volts voltage logic high enable v eh 2.0 20 volts voltage
5 dc electrical specifications for 0 c t a 70 c, 4.5 v v cc 20 v, v e = 0.8 v, all typicals at t a = 25 c and v cc = 5 v unless otherwise noted. see note 13. parameter symbol min. typ. max. units test conditions fig. note mark state input i mi 12 ma 2, 3, current 4 mark state input v mi 2.52 2.75 volts i i = 20 ma v e = don?t care 4, 5 voltage space state input i si 3 ma 2, 3, current 4 space state input v si 1.6 2.2 volts i i = 0.5 to 2.0 ma v e = don?t 2, 4 voltage care input hysteresis i hys 0.3 0.8 ma 2 current logic low output v ol 0.5 volts i ol = 6.4 ma i i = 3 ma 6 voltage (4 ttl loads) logic high output v oh 2.4 volts i oh = -2.6 ma, i i = 12 ma 7 voltage output leakage i ohh 100 m av o = 5.5 v i i = 20 ma 500 m av o = 20 v logic high enable v eh 2.0 volts voltage logic low enable v el 0.8 volts voltage logic high enable i eh 20 m av e = 2.7 v 100 m av e = 5.5 v 0.004 250 m av e = 20 v logic low enable i el -0.32 ma v e = 0.4 v current logic low supply i ccl 4.5 6.0 ma v cc = 5.5 v i i = 0 ma 5.25 7.5 ma v cc = 20 v logic high supply i cch 2.7 4.5 ma v cc = 5.5 v i i = 20 ma 3.1 6.0 ma v cc = 20 v high impedance i ozl -20 m av o = 0.4 v v e = 2 v, i ozh 20 m av o = 2.4 v 100 m av o = 5.5 v 500 m av o = 20 v logic low short i osl 25 ma v o = v cc = 5.5 v i i = 0 ma 5 40 ma v o = v cc = 20 v logic high short i osh -10 ma v cc = 5.5 v i i = 20 ma 5 -25 ma v cc = 20 v input capacitance c in 120 pf f = 1 mhz, v i = 0 v dc, pins 1 and 2 current (v out > v cc ) current current state output current current circuit output current circuit output current i i = 20 ma v o = gnd v cc = 4.5 v v e = don?t care v e = don?t care
6 switching specifications for 0 c t a 70 c, 4.5 v v cc 20 v, v e = 0.8 v, all typicals at t a = 25 c and v cc = 5 v unless otherwise noted. see note 13. parameter symbol min. typ. max. units test conditions fig. note propagation delay time t plh 0.23 1.6 m sv e = 0 v, 8, 9, 7 to logic high output level c l = 15 pf 10 propagation delay time t phl 0.17 1.0 m sv e = 0 v, 8, 9, 8 to logic low output level c l = 15 pf 10 propagation delay time t plh - t phl 60 ns i i = 20 ma, 8, 9, skew c l = 15 pf 10 output enable time to t pzl 25 ns i i = 0 ma, 12, 13, logic low level c l = 15 pf 15 output enable time to t pzh 28 ns i i = 20 ma, 12, 13, logic high level c l = 15 pf 14 output disable time to t plz 60 ns i i = 0 ma, 12, 13, logic low level c l = 15 pf 15 output disable time to t phz 105 ns i i = 20 ma, 12, 13, logic high level c l = 15 pf 14 output rise time t r 55 ns v cc = 5 v, 8, 9, 9 (10-90%) c l = 15 pf 11 output fall time t f 15 ns v cc = 5 v, 8, 9, 10 (90-10%) c l = 15 pf 11 common mode transient |cm h | 1,000 10,000 v/ m sv cm = 50 v (peak) 16 11 immunity at logic high i i = 12 ma, output level t a = 25 c common mode transient |cm l | 1,000 10,000 v/ m sv cm = 50 v (peak) 16 12 immunity at logic low i i = 3 ma, output level t a = 25 c package characteristics for 0 c t a 70 c, unless otherwise specified. all typicals at t a = 25 c. parameter symbol min. typ. max. units test conditions fig. notes input-output momentary v iso 2500 v rms rh 50%, t = 1 min, 6, 14 withstand voltage* t a = 25 c resistance, input-output r i-o 10 12 ohms v i-o = 500 v dc 6 capacitance, input-output c i-o 1.0 pf f = 1 mhz, v i-o = 0 v 6 *the input-output momentary withstand voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating. for the continuous voltage rating refer to the vde 0884 insulation characteristics table (if applicable), your equipment level safety specification, or agilent application note 1074, optocoupler input-output endurance voltage.
7 notes: 1. 1 m s pulse width, 300 pps. 2. derate linearly above 70 c free air temperature at a rate of 1.6 mw/ c. proper application of the derating factors will prevent ic junction temperatures from exceeding 125 c for ambient temperatures up to 85 c. 3. derate linearly above 70 c free air temperature at a rate of 3.8 mw/ c. 4. derate linearly above 70 c free air temperature at a rate of 4.6 mw/ c. 5. duration of output short circuit time shall not exceed 10 ms. 6. the device is considered a two terminal device, pins 1, 2, 3, and 4 are connected together and pins 5, 6, 7, and 8 are connected together. 7. the t plh propagation delay is measured from the 10 ma level on the leading edge of the input pulse to the 1.3 v level on the leading edge of the output pulse. 8. the t phl propagation delay is measured from the 10 ma level on the trailing edge of the input pulse to the 1.3 v level on the trailing edge of the output pulse. 9. the rise time, t r , is measured from the 10% to the 90% level on the rising edge of the output logic pulse. 10. the fall time, t f , is measured from the 90% to the 10% level on the falling edge of the output logic pulse. 11. common mode transient immunity in the logic high level is the maximum (negative) dv cm /dt on the trailing edge of the common mode pulse, v cm , which can be sustained with the output voltage in the logic high state (i.e., v o 3 2 v). 12. common mode transient immunity in the logic low level is the maximum (positive) dv cm /dt on the leading edge of the common mode pulse, v cm , which can be sustained with the output voltage in the logic low state (i.e., v o 0.8 v). 13. use of a 0.1 m f bypass capacitor connected between pins 5 and 8 is recommended. 14. in accordance with ul 1577, each optocoupler momentary withstand is proof tested by applying an insulation test voltage 3 3000 v rms for 1 second (leakage detection current limit, i i-o 5 m a). figure 5. typical input voltage vs. temperature. figure 6. typical logic low output voltage vs. temperature. figure 7. typical logic high output current vs. temperature. v i ?loop voltage ?volts -50 100 2.8 2.2 t a ?ambient temperature c -25 0 25 2.6 50 75 2.4 i i = 12 ma i i = 20 ma v ol ?low level output voltage ?v -60 100 1.0 0 t a ?temperature c -40 0 20 0.7 60 80 0.3 40 -20 0.9 0.8 0.6 0.5 0.4 0.2 0.1 v cc = 4.5 v i i = 3 ma i o = 6.4 ma i oh ?high level output current ?ma -60 100 0 -8 t a ?temperature c -40 0 20 -3 60 80 -6 40 -20 -1 -2 -4 -5 -7 v cc = 4.5 v i i = 12 ma v o = 2.7 v v o = 2.4 v figure 2. typical output voltage vs. loop current. figure 3. typical current switching threshold vs. temperature. i i ?input switching threshold ?ma -50 100 10 0 t a ?ambient temperature c -25 0 25 6 2 50 75 4 i hys 8 figure 4. typical input loop voltage vs. input current.
8 figure 8. test circuit for t phl , t plh , t r , and t f . figure 13. waveforms for t pzh , t pzl , t phz , and t plz . figure 12. test circuit for t pzh , t pzl , t phz , and t plz . figure 9. waveforms for t phl , t plh , t r , and t f . figure 10. typical propagation delay vs. temperature. t p ?propagation delay ?? -60 100 0.5 0 t a ?temperature c -40 0 20 0.3 60 80 0.1 40 -20 0.4 0.2 v cc = 5 v c l = 15 pf t plh t phl t r , t f ?rise, fall times ?ns -60 100 120 0 t a ?temperature c -40 0 20 60 80 40 -20 100 80 60 40 20 t r v cc = 5 v c l = 15 pf t f figure 11. typical rise, fall time vs. temperature. +5 v
9 t p ?enable propagation delay ?ns -60 100 200 0 t a ?temperature c -40 0 20 60 80 40 -20 150 100 50 v cc c l = 15 pf t phz t pzh 20 v 4.5 v 4.5 v 20 v t p ?enable propagation delay ?ns -60 100 100 0 t a ?temperature c -40 0 20 60 80 40 -20 80 60 20 v cc c l = 15 pf t plz t pzl 20 v 4.5 v 4.5 v 20 v 40 figure 14. typical logic high enable propagation delay vs. temperature. figure 15. typical logic low enable propagation delay vs. temperature. figure 16. test circuit for common mode transient immunity. applications data transfer between equipment which employs current loop circuits can be accomplished via one of three configurations: simplex, half duplex or full duplex communication. with these configurations, point-to- point and multidrop arrangements are possible. the appropriate configuration to use depends upon data rate, number of stations, number and length of lines, direction of data flow, protocol, current source location and voltage compliance value, etc. simplex the simplex configuration, whether point to point or multi- drop, gives unidirectional data flow from transmitter to receiver(s). this is the simplest configuration for use in long line length (two wire), for high data rate, and low current source compliance level applications. block diagrams of simplex point- to-point and multidrop arrangements are given in figures 17a and 17b respectively for the hcpl-4200 receiver optocoupler. for the highest data rate per- formance in a current loop, the configuration of a non-isolated active transmitter (containing current source) transmitting data to a remote isolated receiver(s) should be used. when the current source is located at the trans- mitter end, the loop is charged approximately to v mi (2.5 v). alternatively, when the current source is located at the receiver end, the loop is charged to the full compliance voltage level. the lower the charged voltage level the faster the data rate will be. in the configurations of figures 17a and 17b, data rate is independent of the current source voltage compliance level. an adequate compliance level of current source must be available for voltage drops across station(s) during the mark state in multi- drop applications or for long line length. the maximum compliance level is determined by the trans- mitter breakdown characteristic. a recommended non-isolated active transmitter circuit which can be used with the hcpl-4200 in point-to-point or in multidrop 20 ma current loop applications is given in figure 18. the current source is controlled via a standard ttl 7407 buffer to provide high output impedance of current source in both the on
10 figure 17. simplex current loop system configurations for (a) point-to-point, (b) multidrop. and off states. this non-isolated active transmitter provides a nominal 20 ma loop current for the listed values of v cc , r2 and r3 in figure 18. length of current loop (one direction) versus minimum required dc supply voltage, v cc , of the circuit in figure 18 is graphically illustrated in figure 19. multidrop configurations will require larger v cc than figure 19 predicts in order to account for additional station terminal voltage drops. typical data rate performance versus distance is illustrated in figure 20 for the combination of a non-isolated active transmitter and hcpl-4200 optically coupled current loop receiver shown in figure 18. curves are shown for 10% and 25% distortion data rate. 10% (25%) distortion data rate is defined as that rate at which 10% (25%) distortion occurs to output bit interval with respect to input bit interval. an input non-return-to-zero (nrz) test waveform of 16 bits (0000001011111101) was used for data rate distortion measure- ments. data rate is independent of current source supply voltage, v cc . the cable used contained five pairs of unshielded, twisted, 22 awg wire (dearborn #862205). loop current is 20 ma nominal. input and output logic supply voltages are 5 v dc. full duplex the full duplex point-to-point communication of figure 21 uses a four wire system to provide simultaneous, bidirectional data communication between local and remote equipment. the basic application uses two simplex point-to-point loops which have two separate, active, non-isolated units at one common end of the loops. the other end of each loop is isolated. as figure 21 illustrates, the combination of agilent current loop optocouplers, hcpl-4100 transmitter and hcpl-4200
11 figure 18. recommended non-isolated active transmitter with hcpl-4200 isolated receiver for simplex point-to-point 20 ma current loop. receiver, can be used at the isolated end of current loops. cross talk and common mode coupling are greatly reduced when optical isolation is imple- mented at the same end of both loops, as shown. the full duplex data rate is limited by the non- isolated active receiver current loop. comments mentioned under simplex configuration apply to the full duplex case. consult the hcpl-4100 transmitter opto- coupler data sheet for specified device performance. half duplex the half duplex configuration, whether point-to-point or multidrop, gives non- simultaneous bidirectional data flow from transmitters to receivers shown in figures 22a and 22b. this configuration allows the use of two wires to carry data back and forth between local and remote units. however, protocol must be used to determine which specific transmitter can operate at any given time. maximum data rate for a half duplex system is limited by the loop current charging time. these considerations were explained in the simplex config- uration section. figures 22a and 22b illustrate half duplex application for the combination of hcpl-4100/-4200 optocouplers. the unique and complementary designs of the hcpl-4100 transmitter and hcpl-4200 receiver optocouplers provide many designed-in benefits. for example, total optical isolation at one end of the current loop is easily accomplished, which results in substantial removal of common mode influences, elimination of ground potential figure 19. minimum required supply voltage, v cc , vs. loop length for current loop circuit of figure 19. figure 20. typical data rate vs. distance. t a = 25 ? figure 21. full duplex point-to-point current loop system configuration.
differences and reduction of power supply requirements. with this combination of hcpl-4100/ -4200 optocouplers, specific current loop noise immunity is provided, i.e., minimum space state current noise immunity is 1 ma, mark state noise immunity is 8 ma. voltage compliance of the current source must be of an adequate level for operating all units in the loop while not exceeding 27 v dc, the maximum breakdown voltage for the hcpl-4100. note that the hcpl-4100 transmitter will allow loop current to conduct when input v cc power is off. consult the hcpl-4100 transmitter optocoupler data sheet for specified device performance. for more information about the hcpl-4100/-4200 optocouplers, consult application note 1018. figure 22. half duplex current loop system configurations for (a) point-to-point, (b) multidrop. www.semiconductor.agilent.com data subject to change. copyright ? 1999 agilent technologies obsoletes 5954-1036 5965-3580e (11/99)


▲Up To Search▲   

 